La tua regione e la tua lingua sono state selezionate automaticamente. Puoi modificarlo in qualsiasi momento nel menu del sito.
Americas | Italiano

Transducer for Multi-Layer Film Thickness Measurement

Codice art. 94029

BYK-PELT-Transducer SMB
High frequency transducer for tight spaces

  • Measurement range is 10-400 µm
  • Smaller diameter version of transducers MB: 9.271 mm without FlexCap
  • Needs special FlexCap: 94045 BYK-µPELT-FlexCap
  • Used for tight spaces such as automotive window flange measurements

Scegli il tuo modello

Features

Transducers for a wide range of thickness and materials:
We have developed novel fabrication techniques to manufacture, bond and assemble very high frequency elements with an unsurpassed precision, reliability and long service life.

Latest transducer technology is used in Generation II (‘B’ suffix) offering higher sensitivity and resolving power than Generation I. The higher sensitivity enables improvements in the ability to discern lower contrasting layers and the higher resolving power facilitates gauging of thinner layers.

  • Low frequency transducers for thick layers up to 5 mm
  • Medium frequency transducers for layers 18-500 µm
  • High frequency transducers for thin layers down to 5 µm

Technical Attributes

    Technical Specifications

  • Measuring Range Mils / µm
    10 - 400 µm
  • Full Scale Calibration Range Mils/ µm
    -
  • Thickness Measurement

  • Substrato Fe
    yes
  • Substrato Nfe
    yes
  • Couplant
    Application dependent, usually water
  • Range di misura
    10 - 400 µm
  • Diametro esterno
    9.27 mm
  • Range misura temperatura
    0 - 40 °C
  • Range di misura umidità
    0 - 80 % RH
  • General

  • Peso
    0.0074 kg
  • Dimensioni: L x P x A
    0.927 x 1.818 cm
Iscriviti alla nostra Newsletter e tieniti informato! ISCRIVITI