Article No. 3790

byko-test Fe/NFe
Dry film thickness gauge plus humidity & dew point check

  • 4 measurements in one instrument: Film thickness Fe/NFe, Air temperature, Relative humidity, Dew point
  • SSPC specific mode for standardized  measurement protocols and calibration routines

More options

Measurement Method
Certificate
Click here for the Chinese price list in RMB
$849.00 €817.00 excl. taxes & shipping cost

Features

The byko-test film thickness gage includes dew point measurement, whereas the byko-test Lite is for dry-film thickness measurement only.

  • Compact design for one hand operation
  • Color display with 90° and 180° flip screen
  • Automatic substrate recognition
  • Strong wear resistant ruby probe tip
  • Zero, single and two point calibrations
  • Key lock for only taking readings
  • Hi/Low tolerance settings for pass/fail warning
  • Statistics mode with 1000 measurement memory
  • Continous measurement mode
  • Stability mode warns user when instrument is tilted preventing wrong readings

Technical Attributes

    Technical Specifications

  • Measuring Range Mils / µm
    0 - 79 mil 0 - 2,000 µm
  • Measurement Method
    Film Thickness Fe/NFe - Dew Point
  • Full Scale Calibration Range Mils/ µm
    -
  • Certificate
    yes
  • Thickness Measurement

  • Substrate Fe
    Steel or Iron
  • Substrate NFe
    Non-magnetic metals: aluminum, copper, brass, zinc, stainless steel
  • Measuring Range
    0 - 2000 µm
  • Measuring Range
    0 - 79 mil
  • Accuracy

    ±2 µm + 3% of measured value

    ±0,08 mil + 3% of measured value

  • Minimum Curvature
    Convex 5 mm; Concave 30 mm
  • Minimum Curvature
    Convex 0.20 in; Concave 1.2 in
  • Minimum substrate thickness
    Fe: 0,5 mm; NFe: 0,05 mm
  • Minimum substrate thickness
    Fe: 0,019 in; NFe: 0,002 in
  • Temperature Measuring Range
    0 - 50 °C
  • Temperature Measuring Range
    32 - 122 °F
  • Temperature Accuracy
    ±1.5 °C; ±2.7 °F
  • Humidity Measuring Range
    0 - 100 % RH
  • Humidity Accuracy

    20 - 70 %RH: ±4%

    0-19 & 71-100 %RH: ±6%

  • General

  • Memory
    1000 readings
  • Weight
    0.16 kg
  • Weight
    0.35 lb
  • Dimensions: L x W x H
    11.5 x 6.7 x 4.4 cm
  • Dimensions: L x W x H
    4.53 x 2.65 x 1.75 in

Standards

SSPC

SSPC PA2

Delivery Content

Instrument
Zero plates Fe & NFe (3800)
Calibration Shims (5)
Calibration Certificate
2 AA batteries
USB cable (3799)
Data transfer software (3798)
Manual
Carrying case

Knowledge

Film thickness

For all requirements associated with a coating, there is an optimal layer thickness to ensure good flow and leveling, gloss, optimal color uniformity and opacity as well as good protection against environmental influences and corrosion. If the layer thickness is too high, mechanical-technological properties such as mandrel bending tests, stone impact tests and ball impact tests deteriorate, and the cost-effectiveness of the painting process also decreases. For this reason, layer thicknesses are worked out and specified by the paint supplier and quality assurance. These must be regularly checked and documented.

Read more
Subscribe to our Newsletter and stay informed! subscribe